Description
Acetochlor Colloidal Gold Rapid Test Card is a rapid test card that does not require any equipment. It is used to detect the content of acetochlor in agricultural products. The detection threshold of this product is 0.5mg/kg.
[Detection Principle]
The acetochlor rapid detection card applies the principle of competitive inhibition immunochromatography. The acetochlor in the sample binds to the specific monoclonal antibody labeled with colloidal gold during the flow process, inhibiting the antibody and acetochlor on the NC membrane detection line. Binding of amine-BSA conjugates. If the content of acetochlor in the sample is greater than or equal to 0.5mg/kg, the test line (T) has no red band and the result is positive; otherwise, the test line (T) shows a red band and the result is negative.
[Result Judgment]
- Negative: The quality control line (C) shows a red band, and the test line (T) also shows a red band.
- Positive: The quality control line (C) shows a red band, while the test line (T) shows no red band.
- Invalid: If the quality control line (C) does not show color or only the detection line (T) shows color, it means that the operation process is incorrect or the test card is invalid.
[Detection Limit]
0.5mg/kg
[Storage Conditions and Expiration Date]
Store in a cool and dry place at 4~30℃, protected from light; the validity period is 18 months (see the box for production date and batch number).
Specification:50T