Description
This kit uses the double antibody sandwich method to determine the level of human cytomegalovirus PP150 (CMVPP150) in the specimen. Microporous plates were coated with purified human cytomegalovirus PP150 (CMVPP150) antibody to make solid-phase antibodies. Cytomegalovirus PP150 (CMVPP150) was added to the monoclonal antibody-coated microwells in turn, followed by HRP-labeled cytomegalovirus PP150 (CMVPP150) antibody binds to form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with cytomegalovirus PP150 (CMVPP150) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of human cytomegalovirus PP150 (CMVPP150) in the sample was calculated by a standard curve.
Reactivity :Human
Method type : Sandwich ELISA
Detection Range :1.2pg/ml-45pg/ml
Application : ELISA
Purpose : For the quantitative determination of target substances concentrations.
Research Area : Immunology->Innate Immunity->Complement->Alternative Pathway, Immunology->Innate Immunity->Complement->Other
Sample Type : serum, plasma, Urine, tissue samples, cell culture supernates
Plate : Pre-coated,Strips (12 x 8)
Restrictions : For Research Use only
Storage : 2 °C - 8 °C
Storage Comment : Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles
Expiry Date : 12 months
Size : 96T
Availability : 3-5 working days
Precision : Intra-assay Precision (Precision within an assay) CV%<15% Three samples of known concentration were tested twenty times on one plate to assess. Inter-assay Precision (Precision between assays) CV%<15% Three samples of known concentration were tested in twenty assays to assess.
Linearity : To assess the linearity of the assay, samples were spiked with hig3h concentrations of rat ADP in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
Recovery :
Typical Data : These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. ng/ml OD1 OD2 Average 1000 0.088 0.090 0.089 500 0.135 0.142 0.139 250 0.227 0.237 0.232 125 0.324 0.341 0.333 62.5 0.583 0.598 0.591 31.25 0.847 0.864 0.856 15.62 1.228 1.235 1.232 0 2.155 2.199 2.177